Sản Phẩm Trong Giỏ Hàng
  • Bạn chưa có sản phẩm nào trong giỏ hàng
Tổng Hóa Đơn: VNĐ
|
ĐĂNG TIN
 
Đăng tin hoàn toàn miễn phí
 
Quảng cáo liên kết tại RB, EB
 
0% phí khi mua qua Banking/Visa

Máy sinh hóa tự động 400 chất lượng nhất tại tphcm

ID tin: 4164890
Cập nhật: 14/07/2016, lúc 11:04 -

Fully Automated Chemistry Analyzer

Artos Magnum 400 SWEMED


*Reagent tray
-60 reagent positions
-Non-stop cooling system with peltier pad inside,24 hours 2oC-14oC.
-Barcode reader(optional)

*Sampletray
-100 sample positions,micro cup &test tube can be used.
-Barcode reader(optional)


*Reaction tray
-80 reaction cuvettes
-Reaction volume as low as 150 ul
-Stable &acctaretemprature (37+ 0.1oC) for reaction

*Sample probe
-External & internal mirror polish, external & internal probe
-Washing(reduuce carry-over)
-Dedicated sampling probe equipped with sensitive liquid sensor,timely feedback of reagent &sample residuals
-Collision protection
-Automatic probe depth adjusting
*Excellent mixer design
-Teflon coating mixer.No water dropping (reducing carry-over)
-Excelent mixing effect with standard mixing procedure
*Washing station
-7 needles wash-station
-Twice washing
-Effective washing to ensure accurate result and vaild diagnostics
*High Precision ceramic syringe

-Sample dispensing by frequency converting design
-Premannent ceramic piston
-Accurate dispensing as low as 0.1 ul
-Sample Volume :2-30ul,step by 0.1ul
-Reagent Volume:10-300ul,step by 1ul
*Powerful Software
-User friendly software interface simple,easy-to-operation
-Sample automatic dilution(decrease,increase,normal)
-Masking tests when reagent or standard is exhausted
Calibration auto-dilution Linear & nonlinear calibration
Multi-points calibration up to 8 point
Quality control apply to Westgard,L-T plot,Cumulative
Adilute and re-test when linear limit is out of range Automatic dilute and re-test when linear range is out of range Freely set the auto dilute ratio and dilute water position


Real-time display of running status
Real-time display of status of reagent tary,sample tray and reaction tray
Real-time updating of reagent residuals Real-time marking of defective cuvette
Reaction result automatic checking and warning Calibration result automatic cheking and warning
Alarmlog: Automaticalarmandrecordinalarm list with explanations during running process


*Technical specifications

1. General information

Machine type: Random Access, open reagent
Test speed: Constand 400Test/Hour
Test Princeple: Colorimetric method, turbidimetry
Test methos: 1 point end, 2 point end, fixed time , kinetics
Calibration Type: Linear & nonlinear


2. Sample & reagent unit

Sample tray: 100 Sample positions
Sample cup tupe: Micro cup & test tube
Reagent tray: 60 reagent positions
Sample volume: 2-30 ul, step by 0.1 ul
Reagent volume: 10-300 ul, step by 1ul
Sample & reagent bar code reader

3. Optical system


Light source: Halogen lamp
Wavelength: 340nm, 405nm, 450nm, 505nm, 546nm, 578nm, 620nm, 660nm, 690nm
Absorbance range: 0-4.0 Abs
Resolution: 0.0001Abs
Reaction unit
Reaction tray: 80 high quality plastic cuvettes
Reaction volume: 150 – 350 ul
Reaction time: 10 minutes
Temperature: Peltier pad incubation system reaction temperature (37+0.1oC)
Cuvette washing: 2*6 step automatic washing



Liên hệ:

Ms.ThanhThao

international Sale

Telephone : +84.08.38.42.12.15

Mobile : +84.0938277238

Email :sale06@mdscorps.com

Website :mdsgroup.vn

MDS Electronic & Biotechnology Co.,LtD

Add: No.95/20 Pho QuangStr , Ward 2, Tan BinhDist , Ho Chi Minh City
Tin đăng liên quan